High tension spark transformer according to DIN EN 61558-2-3:2011 for ignition of
burners and igniters, designed with separate winding and PE-terminal.
| Type | AF 700 T 20 | AF 800 T 10 | AF 900 T 10 | AF 800 T 51 |
| Ignition | electrode against earth |
electrode against earth |
electrode against earth |
electrode against earth |
| Supply voltage | standard: 220/230 V AC, 50/60 Hz optional: 110/120 V AC, 50/60 Hz |
standard: 220/230 V AC, 50/60 Hz optional: 110/120 V AC, 50/60 Hz |
standard: 220/230 V AC, 50/60 Hz optional: 110/120 V AC, 50/60 Hz |
standard: 220/230 V AC, 50/60 Hz optional: 110/120 V AC, 50/60 Hz |
| Power rating | 2 x 100 VA | 100 VA | 100 VA | 100 VA |
| Ignition voltage | 2 x 5 kV | 5 kV | 5 kV | 5 kV |
| Duty cycle | 20 % | 20 % | 100 % | 20 % |
| Protection rating | IP 65 | IP 65 | IP 65 | IP 65 |
| Dimensions W x H x D | 162 x 162 x 95 mm |
122 x 122 x 85 mm |
162 x 162 x 95 mm |
122 x 122 x 85 mm |
| Housing | cast aluminium | cast aluminium |
cast aluminium | cast aluminium |
| Remarks | Ignition: electrode against electrode possible |
Ignition: electrode against ground |
Ignition: electrode against ground |
For igniters with combined spark/ flame rod |
|