Extractive Automatic Measuring System (AMS) for continuous analysis of total mercury in stack gas or process gas
|
|
| Measurand | Total mercury |
| Measuring range | 0–45 ... 0–500 µg/Nm³ |
| Measuring principle | UV absorption |
| Flue gas temperature | 0–250°C |
| Flue gas pressure | -50 bis +50 hPa |
| Duct diameter | >0,5 m |
| Ambient temperature | +5 bis +30°C |
| Protection | IP40 (IP55) |
| Measuring outputs | 2 x 0 / 4–20 mA/500 Ohm |
| Digital outputs | 4 relay outputs, permissable load 250 V, 100 VA |
| Digital inputs | 1 potential free outputs |
| Accuracy | < 1% of measuring range |
| Detectable limit | < 1 µg/Nm³ |
| Temporary change of sensitivity | < ± 2% of measuring range per month |
| Temporary change of zero offset | < ± 1,4% of measuring range per month, zero offset (automatic) |
| Power supply | 230 VAC, 50 Hz, 1200 W, sampling probe: 650 W, sampling line: 100 W/m |
| Dimensions (H x W x D) | Cabinet 1600 x 800 x 500 mm |
| Weight | approx. 195 kg |